Timing chart
1. When the power is turned ON, the indeterminate state is held until the external trigger
input turns ON.
2. When the external trigger input turns ON (rising edge), half the difference between the
minimum value (B1)and maximum value (P1)of normal measured values (NORM.V) that
occur during the sampling interval is held as the judgment value (JUDGE.V).
3. If the reset input turns ON, the indeterminate state is held.
4. Judgment output outputs the judgment result based on the output setting.
* When the calculation function is used, calculation value "CALC" is shown instead of normal
measured value (NORM.V).
Setting items
Setting item
Measurement mode
(MEAS)
5-38
)
Set values
Sample hold (S-H)
Peak hold (P-H)
Bottom hold (B-H)
Peak to peak hold (P-P)
Peak to peak hold / 2 (P-P/2)
NG hold (NG-H)
Self sample hold (SLF.S-H)
Self peak hold (SLF.P-H)
Self bottom hold (SLF.B-H)
Default value
S-H