5.4 Calculation Settings (
Application
Torsion (TORSIN)
Curvature
(CURVEA)
Thickness (THICK)
The CALC status mark lights on a controller that is performing calculation.
● If more than the specified number of slave units are connected when "TORSIN" (torsion),
"CURVEA" (curvature), or "THICK" (thickness) is selected, the specified number of slave units
closest to the master unit will be used for calculation.
Slave units other than those units will not be used.
■
Setting method
5-76
) (Master Unit Only)
The measured value of the master unit is subtracted from the measured
value of the slave unit. The result is output from the slave unit.
[Calculated value] = [Slave unit n] - [Master unit]
Measures four locations and calculates the amount of torsion. The result
is the calculated value.
[Calculated value] = ([Master unit] - [Slave unit 1] - [Slave unit 3] - [Slave
unit 2])
Measures three locations and calculates the amount of curvature. The
result is the calculated value.
[Calculated value] = ([Master unit] + [Slave unit 2]) ÷ 2 - [Slave unit 1]
The measured object is pressed from above and below by the master unit
and a slave unit, and the measured values of the master unit and slave
unit are summed.
[Calculated value] = [Master unit] + [Slave unit 1]
Function
Number of
slave units
3 units
2 units
1 units
WUME-HGS-11