3-2-2

Extension and Dismantling of Sensor (Series Connection)

This section explains the connection method for series connection using optional parts.
To establish series connection, it is necessary to follow the procedure given below.
<Extension of sensor>
Do not lose any screws during extension / dismantling.
Further, do not mix emitters and receivers to mount in series connection.
Connect the cable for series connection (SF4A-CSL□).
1. Remove two flat countersunk head screws [M3 (length 5mm)] to detach the end cap from
the main side sensor (emitter and receiver to which the synchronization line has been
connected).
2. Remove two flat countersunk head screws [M3 (length 5mm)] to detach the bottom cap
cable from the sub side sensor.
3. Connect the cable for series connection with four flat countersunk head screws [M3
(length 5mm)] at the place from which the parts were removed in Steps 1 and 2 above.
(Tightening torque: 0.5N·m or less)
 When connecting, take care that the cable for series connection (SF4A-CSL□)
 The cable for series connection (SF4A-CSL□) cannot be extended.
- 46 -
has a main side and a sub side. The connector on the main side is male type (pin
side).
© Panasonic Industrial Devices SUNX Co., Ltd. 2013 MJE-SF4A No.0038-55V