5.3 Advanced Settings (
Timing chart
1. The judgment output is held when the external trigger is OFF, but the judgment value
(JUDGE.V) is not held. The judgment output hold state is released by reset input. While
the external trigger is ON, the judgment value (JUDGE.V) and judgment output are held.
2. Reset input causes the judgment value (JUDGE. V) to become indeterminate until the
average count is reached.
3. If the reset input turns ON while the external trigger is ON, the indeterminate state is held.
If a setting change causes the response time or judgment value (JUDGE. V) to change
while the external trigger is ON, reset occurs and the indeterminate state is held.
4. Judgment output outputs the judgment result according to the output setting.
● Once a HIGH judgment is output during one output judgment interval, a LOW judgment is not
output.
Once a LOW judgment is output, a HIGH judgment is not output.
● The trigger mode setting is invalid for NG hold.
Setting item
Setting item
Measurement mode
(MEAS)
5-40
)
Set values
Sample hold (S-H)
Peak hold (P-H)
Bottom hold (B-H)
Peak to peak hold (P-P)
Peak to peak hold / 2 (P-P/2)
NG hold (NG-H)
Default value
S-H