Response Time - Panasonic HG-S Series User Manual

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

● If the lever ratio is set to a value outside the range, "
MAIN (white).
You will then return to the lever ratio setting screen. Set a valid value for the lever ratio.

5.2.11 Response Time (

You can set the time until the judgment value (JUDGE.V) is finalized (response time) when the
sensor head starts measurement.
The response time setting determines the average count and average time of measurement as
shown below.
Response time (ms)
3
5
10
100
500
1000
When the Average count is set to 8 times
● To respond to instantaneous changes, set a shorter response time. To disregard instantaneous
changes, set a longer response time.
● When the reset input is ON, it will be in an indeterminate state "
is reached.
● If the response time is "3" (3 ms), the indeterminate state "
WUME-HGS-11
)
Average count
(repetitions)
1
3
8
96
480
960
5.2 Basic Settings (
" will appear in the digital display /
Average time (ms)
1
3
8
96
480
960
" until the average count
" will be maintained for 1 ms.
Internal value update
cycle (ms)
1
1
1
4
16
32
5-23
)

Advertisement

Table of Contents
loading

Table of Contents