6-9 Sequence I/O Signal

Outline of Operation
 You can set sequences in various operating conditions.
 For the connection of I/O signals and processing of external signals, refer to "Control I/O
Connector Specifications (CN1)" (P.3-18).
Input Signals
You can allocate any function of input signals to the input pins for the control I/O connector
(CN1). In addition, you can change logic. However, refer to "Input Signal Allocation Method"
(P.6-36) for more information because some signals have allocation limitations.
If a G-series Servo Drive is being replaced with a G5-series Servo Drive, use the G5-series
Servo Drive with the default settings.
Input Signal Default Setting
The allocations of the default input signals are as follows. Refer to "Input Signal Allocation
Method" when you change the allocation to use.
Applicable
Input
parameters
signals
Pn400
SI1 input
Pn401
SI2 input
Pn402
SI3 input
Pn403
SI4 input
Pn404
SI5 input
Pn405
SI6 input
Pn406
SI7 input
Pn407
SI8 input
Pn408
SI9 input
Pn409
SI10 input
Contacts NO and NC in the logic fields indicate the following statuses.
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Position control or
Factory
fully-closed
default
control
setting (hex)
Signal
name
00828282h
NOT
NC
(8553090)
00818181h
POT
NC
(8487297)
0091910Ah
DFSEL1
NO
(9539850)
00060606h
GSEL
NO
(394758)
0000100Ch
GESEL1
NO
(4108)
00030303h
RUN
NO
(197379)
00000f07h
ECRST
NO
(3847)
00040404h
RESET
NO
(263172)
00050505h
TVSEL
NO
(328965)
00000E88h
IPG
NC
(3720)
6-9 Sequence I/O Signal
Default setting state
Speed control
Signal
Logic
Logic
name
NOT
NC
POT
NC
VZERO
NC
GSEL
NO
VSEL3
NO
RUN
NO
VSEL2
NO
RESET
NO
TVSEL
NO
VSEL1
NO
Torque control
Signal
Logic
name
NOT
NC
POT
NC
VZERO
NC
GSEL
NO
RUN
NO
RESET
NO
TVSEL
NO
6-35
6