Download Print this page

Omron R88D-KTA5L User Manual page 135

Ac servomotors/servo drives

Advertisement

R88D-KT75F
Terminal Block Specifications, Left Terminal Block (TB1)
Symbol
L1
Main circuit power supply
L2
input
L3
External Regeneration
B1
Resistor connection
B2
terminals
NC
Do not connect.
U
V
Motor connection
W
terminals
Terminal Block Specifications, Right Terminal Block (TB2)
Symbol
24 V
Control circuit power
supply input
0 V
DB1
Dynamic brake resistance
control terminals
DB2
DB3
DB4
Frame ground
Precautions for Correct Use
 Tighten the terminal block screws to the torque of 1.5 N•m (M5).
 If the torque for terminal block screws exceeds 2.0 N•m (M5), the terminal block may be damaged.
 Tighten the fixing screw of the terminal block cover to the torque of 0.2 N•m (M3).
 Tighten the ground screws to the torque of 1.4 to 1.6 N•m (M5).
 Never connect an External Regeneration Resistor between the B1 and NC terminals
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Name
R88D-KT@F (7.5 kW): 3-phase 380 to 480 VAC (323 to 528 V) 50/
60 Hz
Connect an External Regeneration Resistor between B1 and B2.
Red
These are the output terminals to the Servomotor.
Be sure to wire them correctly.
White
Blue
Green/
Yellow
Name
24 VDC±15%
These terminals are used to control the MC for externally
connected dynamic brake resistance. The output contact
specifications are 1 A max. at 300 VAC/100 VDC max. Connect
them if required.
Normally DB3 and DB4 are connected. When using an externally
connected Dynamic Brake Resistor, remove the short bar from
between DB3 and DB4.
This is the ground terminal. Ground to 10 Ω or less.
3-1 Servo Drive Specifications
Function
Function
3
3-16

Hide quick links:

Advertisement

loading