Omron R88D-KTA5L User Manual page 443

Ac servomotors/servo drives

Advertisement

Pn010
Electronic Gear Ratio Denominator
Setting
30
1 to 2
range
 Set the electronic gear function.
· It is enabled when Pn008 is 0.
 The electronic gear can be used for the following:
· To set the amount of motor rotation or travel distance per input command pulse.
· To increase the nominal command pulse frequency by using a multiplier when the desired
motor speed cannot be achieved due to the limited pulse generation capability of the host
device (possible maximum output frequency).
 Electronic Gear Block Diagram:
Command
counts
f
*1. Numerator 2 to 4 is selected using the electronic gear switching (GESEL1 and GESEL2).
GESEL1
OFF
ON
OFF
ON
Any values can be set for PN008, Pn009, and Pn010, but operation may not be correct if you
set an extreme electronic gear ratio. Set the electronic gear ratio to between 1/1,000 and
1,000. Refer to "6-4 Electronic Gear Function" (P.6-10) for information on the settings.
Pn011
Encoder Dividing Numerator
Setting
1 to 262,144
range
 If Encoder Dividing Denominator (Pn503) = 0, the encoder resolution becomes the pulse output dividing denominator.
 Note that 1 pulse corresponds to 4 counts. Encoder resolution corresponds with counts.
Encoder pulse →
Pn012
Encoder Output Direction Switching Selection
Setting
0 to 3
range
 Set the phase-B logic and output source for pulse output. For fully-closed control, select an
external encoder for the output source. For other control modes, set the encoder.
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Unit
Numerator 1 (Pn009)
*1
Numerator 2 (Pn500)
Internal
Numerator 3 (Pn501)
*1
command
Numerator 4 (Pn502)
*1
F
Denominator (Pn010)
Feedback
counts
(resolution)
GESEL2
OFF
Electronic Gear Ratio Numerator 1
OFF
Electronic Gear Ratio Numerator 2
ON
Electronic Gear Ratio Numerator 3
ON
Electronic Gear Ratio Numerator 4
Unit
P/r
Pn011×4 (When the host side uses a 4 multiplier process)
Encoder resolution
Unit
8-1 Basic Parameters
Default
10000
setting
+
To error
counter
20
2
count/rev
or
17
2
count/rev
Selected numerator
Default
2500
setting
→ Output pulse
Default
0
setting
Position
Power OFF
and ON
8
All
Power OFF
Yes
and ON
All
Power OFF
Yes
and ON
8-6