Terminal Block Wiring Procedure
On a Servo Drive with 2.0 kW or less, connector-type terminal blocks are used.
The procedure for wiring these terminal blocks is explained below.
1. Remove the terminal block from the Servo Drive before wiring.
The Servo Drive may be damaged if the wiring is done with the terminal block in place.
2. Strip off 8 to 9 mm of the covering from the end of each wire.
Refer to "Terminal Block Wire Sizes"(P.4-27) for applicable wire sizes.
3. Open the wire insertion slots in the terminal block using a tool.
There are 2 ways to open the wire insertion slots, as follows.
 Pry the slot open using the lever that comes with the Servo Drive. (Figure A)
 Insert a flat-blade screwdriver (end width: 3.0 to 3.5 mm) into the opening for the screwdriver on
the terminal block, and press down firmly to open the slot. (Figure B)
4. With the wire insertion slot held open, insert the end of the wire.
After inserting the wire, let the slot close by releasing the pressure from the lever or the
screwdriver.
5. Mount the terminal block to the Servo Drive.
After all of the terminals have been wired, return the terminal block to its original position on
the Servo Drive.
Note. Some shapes of the ferrules that are connected to the lines may be difficult to insert into the
connector. If so, use the following methods to insert the ferrules.
 Rotate the connector insertion orientation by 90°.
 Adjust the shape of the ferrules with pliers or other suitable tool and then insert the ferrules.
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Connector-type
terminal block
8 to 9 mm
Figure A
(Example of R88D-KT01H)