Download Print this page

Omron R88D-KTA5L User Manual page 290

Ac servomotors/servo drives

Advertisement

4-2 Wiring
R88D-KT75H
Terminal Block Specifications, Left Terminal Block (TB1)
Symbol
L1
L2
L3
B1
B2
N (NC)
U
V
4
W
Terminal Block Specifications, Right Terminal Block (TB2)
Symbol
L1C
L2C
DB1
DB2
DB3
DB4
Never connect an External Regeneration Resistor between the B1 and N (NC) terminals
4-21
Name
Main circuit power supply
input
External Regeneration
Resistor connection
terminals
Motor connection
terminals
Name
Control circuit power
supply input
Dynamic brake
resistance control
terminals
Frame ground
Precautions for Correct Use
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
R88D-KT@H (7.5 kW): 3-phase 200 to 230 VAC (170 to 253 V) 50/
60 Hz
280 to 325 VDC (238 to 357 VDC)
Connect an External Regeneration Resistor between B1 and B2.
Terminal B1 is main circuit DC output (positive).
These are the output terminals to the Servomotor.
Be sure to wire them correctly.
R88D-KT@H: Single-phase 200 to 230 VAC (170 to 253 V) 50/60
Hz
280 to 325 VDC (238 to 357 VDC)
These terminals are used to control the MC for externally connected
dynamic brake resistance. The output contact specifications are
1 A max. at 300 VAC/100 VDC max. Connect them if required.
Normally DB3 and DB4 are connected. When using an externally
connected Dynamic Brake Resistor, remove the short bar from
between DB3 and DB4.
This is the ground terminal. Ground to 100 Ω or less.
Function
Function

Hide quick links:

Advertisement

loading