Download Print this page

Omron R88D-KTA5L User Manual page 131

Ac servomotors/servo drives

Advertisement

R88D-KT75H
Terminal Block Specifications, Left Terminal Block (TB1)
Symbol
L1
Main circuit power supply
L2
input
L3
B1
External Regeneration
Resistor connection
B2
terminals
N (NC)
U
V
Motor connection
terminals
W
Terminal Block Specifications, Right Terminal Block (TB2)
Symbol
L1C
Control circuit power
supply input
L2C
DB1
Dynamic brake
resistance control
DB2
terminals
DB3
DB4
Frame ground
Precautions for Correct Use
 Tighten the terminal block screws to the torque of 1.5 N•m (M5).
 If the torque for terminal block screws exceeds 2.0 N•m (M5), the terminal block may be damaged.
 Tighten the fixing screw of the terminal block cover to the torque of 0.2 N•m (M3).
 Tighten the ground screws to the torque of 1.4 to 1.6 N•m (M5).
 Never connect an External Regeneration Resistor between the B1 and N (NC) terminals
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Name
R88D-KT@H (7.5 kW): 3-phase 200 to 230 VAC (170 to 253 V) 50/
60 Hz
280 to 325 VDC (238 to 357 VDC)
Connect an External Regeneration Resistor between B1 and B2.
These are the output terminals to the Servomotor.
Be sure to wire them correctly.
Name
R88D-KT@H: Single-phase 200 to 230 VAC (170 to 253 V) 50/60
Hz
280 to 325 VDC (238 to 357 VDC)
These terminals are used to control the MC for externally connected
dynamic brake resistance. The output contact specifications are
1 A max. at 300 VAC/100 VDC max. Connect them if required.
Normally DB3 and DB4 are connected. When using an externally
connected Dynamic Brake Resistor, remove the short bar from
between DB3 and DB4.
This is the ground terminal. Ground to 100 Ω or less.
3-1 Servo Drive Specifications
Function
Function
3
3-12

Hide quick links:

Advertisement