4-3 Wiring Conforming to EMC Directives
Door Structure
 Use a metal door.
 Use a water-draining structure where the door and case fit together, and leave no gaps. (Refer to
the diagrams.)
 Use a conductive gasket between the door and the case. (Refer to the diagrams.)
 Strip the paint off the sections of the door and case that will be in contact with the conductive
gasket (or mask them during painting), so that they are electrically conductive.
 The panel may warp and gaps may appear when screws are tightened. Be sure that no gaps
appear when tightening screws.
Case
A
4
[Door (interior side)]

Selecting Connection Component

This section explains the criteria for selecting the connection components required to improve noise resistance.
Understand each component's characteristics, such as its capacity, performance, and applicable range when
selecting the connection components.
For more details, contact the manufacturers directly.
No-fuse Breaker (NFB)
When selecting a no-fuse breaker, consider the maximum input current and the inrush current.
Maximum Input Current
 The momentary maximum output of the Servo Drive is approx. 3 times the rated output, and can
be output for up to 3 seconds.
Therefore, select no-fuse breakers with an operation time of at least 5 seconds at 300% of the
rated current ratio. General and low-speed no-fuse breakers are generally suitable.
4-41
Door
B
[Control panel]
Oil-resistant gasket
Conductive gasket
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Oil-resistant gasket
Conductive gasket
[A-B cross-section diagram]
Door end