FM Deviation Numeric Results Window
Name
FM Deviation
Modulation Rate
Modulation Distortion
Modulation SINAD
4.4.5.1 SPAN/X Scale
The SPAN/X Scale key accesses the menu to set the desired horizontal scale and associated settings of the
waveform.You must have the Demod Waveform selected under the Trace/View key.
4.4.5.1.1 Scale/Div
This key is for Scale/Div control
Mode:
Key Path:
Remote Command:
Unit:
Preset:
State Saved:
Min:
Max:
Dependencies/Couplings:
Notes:
Example:
Chapter 4
Corresponding Results
N=1 1st
FM Deviation output
n=1 3rd
n=1 4th
n=1 5th
MRECEIVE
Span X Scale
:DISPlay:FMDeviation[1]|2:WINDow[1]|2|3|4:TRACe:X[:SCALe]
:PDIVision <seconds>
:DISPlay:FMDeviation[1]|2:WINDow[1]|2|3|4:TRACe:X[:SCALe]
:PDIVision?
Seconds
100us
Saved in instrument state.
–10 s
1 s
See Restriction and Notes
If the Scale Coupling is set to On, this value is automatically determined by the
measurement result. When you set this value manually, Scale Coupling
automatically changes to Off.
:DISP:FMD:WIND:TRAC:X:PDIV 100us
:DISP:FMD:WIND:TRAC:X:PDIV?