And-Zone Groups - Bentel Security Kyo 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for Kyo 320:
Table of Contents

Advertisement

spec ti vely, to ena ble or di sa ble the re spec ti ve at tri bu te.
The di splay will show the at tri bu te sta tus: "û" me ans
Acti ve, "-" NOT ac ti ve.
7b. Press ENTER.
Cycles
Repetitive
This pro gram ming field will al low you to pro gram the
num ber of ti mes the zone will ge ne ra te the Alarm on
zone - Via Ra dio event.
Va lid en tries: 1 thro ugh 254 or Re pe ti ti ve.
8b. Enter the re qui red num ber of cycles, or en ter all ze -
ros to set Re pe ti ti ve, then press ENTER.
All.message ---
None
This pro gram ming sec tion will al low you to as sign two
vo i ce mes sa ges (from the 62 ava i la ble) to the wi re less
zone be ing pro gram med. You can as sign one mes sa ge
to Standby sta tus and anot her to Alarm sta tus.
If you se lect "None" in the Alarm Mes sa ge field, Alarm
sta tus will be si gnal led by two be eps, when the system
is ac ces sed over the pho ne.
If you se lect "None" in the Standby Mes sa ge field,
Standby sta tus will be si gnal led by one beep, when the
system is ac ces sed over the pho ne.
9b.Using A or B, se lect the mes sa ge num ber or
"None", then press ENTER.
10b. For the Standby mes sa ge, re pe at step 9b, then
press ENTER.
Stdby mes.n. ---
None
11b. Assign the Zone to the re spec ti ve Par ti tions (re fer
to "Ena bling Par ti tions and A, B, C and D Mode" un der
"Using the Key pad"), then press ENTER.
Partition
1-8
x
12b.Using A or B, se lect the Ena ble au to arm op tion
(re fer "Auto-arm on de lay") or Full ar ming Al. (re fer
to "Full Arming Alarm"). Using ON or OFF, re spec ti vely,
ena ble or di sa ble the op tion con cer ned.
Press ENTER to con firm and go to the next step.
Options
Enable autoarm -
13b.If the Ena ble Au to arm op tion is OFF, go to step
14b. If the Ena ble Au to arm op tion is ON, en ter the re -
qui red ti me o ut (re fer to "Inac ti vity Time"), then press E
to con firm and con ti nue.
24
Timeout
Disabled
14b.Enter the Inac ti vity Time (re fer to "Inac ti vity").
Using 0, se lect Di sa bled to di sa ble Inac ti vity su per vi -
sion.
Inac ti vity time
Di sa bled
Press ENTER to con firm and con ti nue.

AND-zone Groups

This pro gram ming sec tion will al low you to cre a te up to
32 AND-Zone gro ups. Each AND-Zone gro up can in -
clu de up to 8 Zo nes. If a Zone is in clu ded in an
AND-Zone gro up it will ge ne ra te Alarms ONLY when
ALL the Zo nes in the Gro up are vio la ted wit hin a set
time
(re fer
to
"Zo nes
"PROGRAMMING").
From the PROGRAMMING menu:
PROGRAMMING
Configuration
1. Using A or B, se lect the AND-Zone Gro ups op tion.
PROGRAMMING
AND-Zone Groups
2. Press ENTER.
AND-Zone Groups
Nu mber
01
3. The di splay will show the ID Num ber of the first
AND-Zone Gro up. If you re qui re a dif fe rent AND-Zone
Gro up, use A or B, or en ter the re spec ti ve ID Num ber,
then press ENTER. To exit this pro gram ming sec tion,
press ESC.
AND-Zone
1___
Zone
001
4. Using A or B, se lect the first Zone to be in clu ded in
the AND-Zone Gro up, or en ter the re spec ti ve 3 di git
Zone ID Num ber (for exam ple, en ter 003 for Zone 3).
Press ENTER to go to the suc ces si ve pro gram ming
field.
+
NOTE: To de le te an AND-Zone from a Gro up, en -
ter 000 in the re spec ti ve pro gram ming field.
AND-Zone Window
hh.mm.ss00.00.00
5. Once the AND-Zone Gro up has been set up, pro -
gram the AND-Zone Win dow (in ho urs, mi nu tes and
se conds ). The system will not ge ne ra te Alarms un less
in
AND
Mode"
un der
KYO320