Reset Alarms And Tamper; Stop Alarms; Arm/Disarm; Zone Status - Bentel Security Kyo 320 User Manual

Hide thumbs Also See for Kyo 320:
Table of Contents

Advertisement

+
Your Installer has programmed your Control panel
with your requirements in mind. Therefore, some of
the options may not be available
This system can manage 195 User Codes. Only the first
User Code (0001) is Active and can operate the
system.
Your Installer will enable and program as many User Co-
des as necessary. The programmed Access Level defi-
nes the User Code Partitions (the Partitions the User
Code can control) and the User Code options (the options
the User Code can access). The menu will show the op-
tions the entered User Code is enabled for.
The following paragraphs describe all the Options on
the User menu.
+
The commands will affect ONLY the common Par-
titions of the User Code and Keypad concerned.
n Reset Alarms and Tamper
This command will allow you to restore all Alarm signal-
ling devices to Standby, and delete the zone and Parti-
tion Alarm memories.
Once the command has been executed, the display will
show the following message:
USER MENU
done!
If Alarm signalling persists after a Reset Alarms com-
mand, select the Stop Alarms option. The causes of
persistent Alarms must be cleared immediately.
n Stop Alarms
This command will allow you to stop and freeze all the
Alarm signalling devices. This status can be undone by
pressing any key. During this phase the Control panel
will be unable to trigger Alarms, and the display will
show the following message:

STOP ALARMS!

STOP ALARMS!
The first line flashes while the second remains fixed.
The I indicators on Keypads, assigned to any of the
Partitions of the Keypad concerned, will blink.
n Arm/Disarm
This command will allow you to Arm or Disarm the Parti-
tions one by one, as follows:
Figure 2 Partition status.
10
This line will blink
This line will be solid
1. Use A and B to scroll the Partitions common to both
the Keypad and User Code concerned (the current sta-
tus will be indicated on the second line).
Partition
001
disarmed
x
meanings of the X's that may appear on the second line
can be found in Figure 2.
2. Press the ENTER key to select the required Partition.
The display will show the Arming options, as follows:
1=AWAY
2=STAY
3=STAY_0
4=DIS
3. Press the relevant key to select the required mode:
1 - Away
2 - Stay
3 - Stay with 0 delay
4 - Disarm
4. Press the ESC key to step back to the User menu.
n Zone status
This command will allow you to turn ON/OFF
(UnBypass/Bypass) the zones of the User Code Partitions.
The
display
will
show
UNBYPASSED status, and the current condition of the
zone, as follows:
Ø ALARM (Alarm conditions present)
Ø TAMPER (Tamper conditions present e.g. Wires cut)
Ø SHORT (Tamper conditions present e.g. Short-circuit)
Ø STBY (zone in standby status)
+
NOTE: You must call your Installer if any zones si-
gnal Tamper or Short-circuit.
1. Use A and B to scroll the zones of the Partitions com-
mon to the Keypad and User Code concerned.
zone n.
002
sitting room
2. Press the ENTER key to select the required zone.
The display will show the zone status, as follows
Sitting room
STBY UNBYPASSED
3. Using the ON and OFF keys UNBYPASS (turn ON)
or BYPASS (Turn OFF) the zone, as required.
4. Use A or B to scroll the zones and continue, or press
the ESC key twice to step back to the User menu.
+
Attempts to Arm (turn ON) the Partitions when zo-
nes are Bypassed or in Alarm status will activate
the Zones status list automatically. Only the zo-
nes that are about to be Armed will be included in
the list.
the
BYPASSED
or
KYO320