Technical data

NOTE
Technical data
 Additional specifications and notices for using the device can be found in the
technical description.
Operating voltage without/with heating
Power consumption without/with heating
Light source / Wavelength
Laser class
Scanning rate
Reading distance
Resolution
Code types
Interface type
Service interface
Switching inputs/outputs
Degree of protection
VDE safety class
Housing
1)
18 ... 30VDC (PELV, Class 2)
4W /
Laser / 655nm
2 (in accordance with IEC 60825-1:2007),
see
1
1000 scans/s
N-optics: max. 160mm,
M-optics: max. 320mm,
F-optics: max. 550mm,
L-optics: max. 700mm,
J-optics: max. 600mm,
see technical description
N-optics: m = 0.127 ... 0.2mm,
M-optics: m = 0.2 ... 0.5mm,
F-optics: m = 0.3 ... 0.5mm,
L-optics: m = 0.35 ... 0.8mm
J-optics: m = 0.5 ... 0.8mm
2/5 Interleaved,
Code 39,
Code 128,
EAN 128,
EAN/UPC,
EAN Addendum,
Codabar,
Code 93,
GS1 DataBar
RS 232,
RS 422,
RS 485,
PROFIBUS DP,
Ethernet,
EtherCAT
PROFINET,
EtherNet/IP,
see
4
USB 2.0 (mini-B socket)
2, configurable
2)
IP 65
III
Diecast aluminum
26W
EN