12.8 SUMMER (Daylight Saving Time Acquisition)

12.8 SUMMER (Daylight Saving Time Acquisition)
Ladder diagram
List of operands
Operand
Description
Starting address of the device that stores clock data when daylight saving time starts (Specify the
clock data in the standard time.)
* The formats of the clock data of S1/S2 are the following four words.
S1
Sx + 0
Sx + 1
Sx + 2
Sx + 3 Minutes
Starting address of the device that stores clock data when daylight saving time ends (Specify the
clock data in the daylight saving time.)
* The formats of the clock data of S1/S2 are the following four words.
S2
Sx + 0
Sx + 1
Sx + 2
Sx + 3 Minutes
Time difference within the daylight saving time period (Unit: minute) Settable range: 0 to 180
S3
(minutes)
* The following eight words are the formats for the enable/disable + clock data of D.
D + 0 Enable/Disable
D + 1
D + 2
D
D + 3
D + 4
D + 5
D + 6
D + 7 Day of the week
12-16
Word
Month
Day
Hours
Word
Month
Day
Hours
Word
Year
Month
Day
Hours
Minutes
Seconds