12.8 SUMMER (Daylight Saving Time Acquisition)
12.8 SUMMER (Daylight Saving Time Acquisition)
■
Ladder diagram
■
List of operands
Operand
Description
Starting address of the device that stores clock data when daylight saving time starts (Specify the
clock data in the standard time.)
* The formats of the clock data of S1/S2 are the following four words.
S1
Sx + 0
Sx + 1
Sx + 2
Sx + 3 Minutes
Starting address of the device that stores clock data when daylight saving time ends (Specify the
clock data in the daylight saving time.)
* The formats of the clock data of S1/S2 are the following four words.
S2
Sx + 0
Sx + 1
Sx + 2
Sx + 3 Minutes
Time difference within the daylight saving time period (Unit: minute) Settable range: 0 to 180
S3
(minutes)
* The following eight words are the formats for the enable/disable + clock data of D.
D + 0 Enable/Disable
D + 1
D + 2
D
D + 3
D + 4
D + 5
D + 6
D + 7 Day of the week
12-16
Word
Month
Day
Hours
Word
Month
Day
Hours
Word
Year
Month
Day
Hours
Minutes
Seconds