Operand
Parameter
[S+2]
Baud rate setting
[S+3]
Data length setting
[S+4]
Parity setting
[S+5]
Stop bit length setting
RS/CS enabled or
[S+6]
disabled
[S+7]
Send waiting time
[S+8]
Start code STX
[S+9]
Terminator setting
Terminator judgement
[S+10]
time
[S+11]
Modem initialization
[S+12]
Reserved area
[S+13]
Communication option
(Note 1)
RS/CS can be selected only when a 1-channel, 5-wire communication cassette (product number
AFP7CCS2) is used.
(Note 2)
The modem is initialized when the power is on, PMSET/pPMSET instruction is executed, and the RUN
mode is turned ON. Initialization is executed only in the first session. (Excluding when the power
supply is turned off and then on again.)
(Note 3)
U3 can be specified only for a built-in SCU. In addition, parity bit is fixed to 0 when data is sent, and
the parity bit is not checked when data is received.
PLC link W0 setting (Setting is enabled when the communication mode is set to the PLC link
mode; only COM1 is enabled)
Operand
Parameter
Link area block
[S+14]
number
PLC link W0 maximum
[S+15]
station number
[S+16]
Range of link relays
WUME-FP7CPUPGR-12
15.8 PMSET / pPMSET (Change of SCU Parameters)
Range
U0 to U10
U0, U1
U0 to U2
U0, U1
U0, U1
(Note 1)
U0 to U10000
U0, U1
U0 to U3
U0 to U10000
U0 to U2
U0
U0, U1
Range
U0, U1
U2 to U16
U0 to U64
Settings
PLC link: U1 to U16 (Default: 0)
U0: 300, U1: 600, U2: 1200, U3: 2400, U4: 4800, U5:
9600, U6: 19200, U7: 38400, U8: 57600, U9: 115200,
U10: 230400 bps
U0: 7-bit length, U1: 8-bit length
U0: No parity, U1: Odd parity, U2: Even parity, U3:
(Note 3)
Parity fixed to 0
U0: 1 bit, U1: 2 bits
U0: Disable, U1: Enable
U0: Immediate Effective time = Un x 0.01 ms (0 to
100 ms)
U0: Disable, U1: Enable
U0: cR; U1: cR+Lf; U2: Time; U3: ETX
U0: For 32 bits
Effective time = Un × 0.01 ms (Only enabled when
the end setting is "Time".)
U0: Not initialize
U1: Execute the first initialization only
U2: Re-execute initialization at the time of setting.
(Note 2)
U0
bit 0: Used to select whether to continue or stop the
PLC link.
0 = The PLC link stops when a communication error
occurs.
1 = The PLC link continues even when a
communication error occurs.
bit 1 to 15: Reserved
Settings
Block number of link relay/link register area
PLC link W0 maximum station number
Specify the range of link relays used for
communication (specification by number of words,
relative values within the specified block)
15-53