Panasonic FP7 Series Command Reference Manual page 945

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

(Note 4)
The retry interval can be specified in 10-second units. It is rounded down to the nearest 10. (Example:
When specifying 38 seconds, it becomes 30 seconds.)
Setting example
Exam
S3
"TOUT=30,RTRY=2,RTTM=500"
ple 1
Settings
Timeout period: 30 seconds, No. of retries: 2, Retry interval: 500 seconds
Exam
S3
"TOUT=270,RTRY=0,RTTM=4900"
ple 2
Settings
Timeout period: 270 seconds, No. of retries: 0 (Not retry), Retry interval: 4900 seconds
Exam
S3
"TOUT=30,RTRY=25"
ple 3
Settings
Timeout period: 30 seconds, No. of retries: 25, Retry interval: Not change
Exam
S3
",RTRY=25,RTTM=3000"
ple 4
Settings
Timeout period: Not change, No. of retries: 25, Retry interval: 3000 seconds
Special keyword of operand [S3] setting
Special keyword
INITIAL
KEEP
Setting example
Exam
S3
"INITIAL"
ple 1
Settings
Timeout period: 60 seconds, Number of retries: 3, Retry interval: 600 seconds
Exam
S3
"KEEP"
ple 2
Settings
Timeout period: Not change, Number of retries: Not change, Retry interval: Not change
Flag operations
Name
Description
Set when a value outside the range is specified for the parameter.
Set when the same keyword is specified redundantly.
To be set when even one request active relay of FTPc control relay or FTPc logging/trace control
relay is 1: Requesting.
SR7
To be set when "Add-on" is set to "Not use" in Built-in ET-LAN setting.
SR8
To be set when server numbers are not specified in the right order.
(ER)
To be set when the slot number [S1] specified with UNITSEL is not 100 (built-in ET-LAN).
Set when executed in an interrupt program.
Set when the number of characters for operand specifying character constant exceeds 256.
Set when the instruction is executed while the specified IP address is incorrect. The detail code
CY
set in SD29 is "1: Specification of incorrect IP address".
(SR9)
To be set when executed during the initialization of Ethernet. The detail code set in SD29 is "11:
Ethernet initialization active".
WUME-FP7CPUPGR-12
17.11 FTPcSV (FTP Client Connected Server Setting)
Description
Set an initial value.
The current setting is not changed.
17-57

Advertisement

Table of Contents
loading