Panasonic FP7 Series Command Reference Manual page 562

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

11.20 FNEG (Floating Point Real Number Data - Sign Changes (Negative/
Positive Conversion))
Processing
Example 1) Operation unit: Single-precision, floating-point real number (SF) (positive real number)
[i]...SF
[S]...DT10
DT10・DT11
DT12・DT13
DT14・DT15
Example 2) Operation unit: Single-precision, floating-point real number (SF) (negative value)
[i]...SF
[S]...DT10
DT10・DT11
DT12・DT13
DT14・DT15
Flag operations
Name
SR7
SR8
(ER)
11-42
[D]...DT2
SF 1.234560E+ + 02
SF 3.456780E+02
SF 5.678900E+02
[D]...DT2
SF -1.234560E+ + 02
SF -3.456780E+02
SF -5.678900E+02
Description
To be set in the case of out-of-range in indirect access (index modification).
To be set when a non-real number is specified for [S].
DT0・DT1
SF 0.000000E+00
DT2・DT3
SF -1.234560E+ + 02
SF 0.000000E+00
DT4・DT5
SF 0.000000E+00
DT0・DT1
SF 1.234560E+ + 02
DT2・DT3
SF 0.000000E+00
DT4・DT5
WUME-FP7CPUPGR-12