17.19 HTTPcCTL (HTTP Client Transfer Control)
Setting of the operands [S1] and [S2]
Setting
Settings
item
Control
S1
target
Control
S2
content
Setting example
Settings
Exam
When enabling the sending
ple 1
of send number 5
Exam
When disabling all sending
ple 2
Exam
When canceling the
ple 3
transfer of ID7
When enabling the sending
Exam
ple 4
of send number 10
(Note 1)
For specifying a device for an operand which can specify character constants, store string data with
SSET instruction excluding a double quotation mark.
Operation of HTTPc control relay
Name
Transfer cancel relay
Transfer disable relay
Transfer request
Transfer active
Transfer retry active
Transfer done
Transfer failed
Transfer direction
17-100
1) When specifying an individual
transfer number
2) When specifying all transfer numbers Specify "ALL".
1) When enabling transfer
2) When disabling transfer
3) When canceling transfer
S1
"ID5"
"ALL"
"ID7"
DT0
Value
DT0
4 (No. of characters)
DT1
H44(D)
(Note 1)
DT2
H30(0)
DT3
Transfer enabled
Not change
OFF
Not change
Not change
Not change
Not change
Not change
Not change
Specify "IDx" with x being a value from 0
to 15.
Specify "ENABLE".
Specify "DISABLE".
Specify "CANCEL".
S2
"ENABLE"
"DISABLE"
"CANCEL"
DT10
DT10
H49(I)
DT11
H31(1)
DT12
DT13
DT14
Transfer disabled
Not change
ON
Not change
Not change
Not change
Not change
Not change
Not change
Value
6 (No. of characters)
H4E(N)
H45(E)
H42(B)
H41(A)
H45(E)
H4C(L)
Transfer canceled
ON
Not change
Not change
Not change
Not change
Not change
Not change
Not change