14.27 EPRINT (Text Creation: With Storage Area Size)
(Note 1)
The start area (storage area size) for [D] is set before executing this instruction.
(Note 2)
The data out of the destination range does not change.
Example 2) When inserting into the text a conversion form (%d) that represents a 16-
bit signed integer
In the place of the conversion form (%d), the ASCII code that is equivalent to the integer data
specified by [S2] is inserted. If a number of digits is not specified for the conversion form, the
number of converted data and the size of the storage area will vary according to the value [S2].
- Image of mail text
Production volume: 5
- Setting values
S1="Production volume: %u"
S2=DT1
D=DT50
U 5
DT1
DT2
DT3
(Note 1)
The start area (storage area size) for [D] is set before executing this instruction.
(Note 2)
The data out of the destination range does not change.
Example 3) When inserting into the text a horizontal tab code (\t: H09)
In the place of the conversion form (\t), the ASCII code that is equivalent to the horizontal tab
code is inserted. If a conversion form is not included in [S1], the data for [S2] will have no effect
on the conversion results.
14-110
DT50
DT51
DT52
H 72 (r)
DT53
H64 (d)
DT54
H 63 (c)
DT55
H 69 (i)
H 6e (n)
DT56
H 76 (v)
DT57
H 6c (l)
DT58
DT59
H 6d (m)
DT60
H 3a (:)
DT61
H 35 (5)
DT62
U 22
U 20
H 50 (P)
H 6f (o)
H 75 (u)
H 74 (t)
H 6f (o)
H 20 (SPACE)
H 6f (o)
H 75 (u)
H 65 (e)
H 20 (SPACE)
(*2)
WUME-FP7CPUPGR-12
Storage area size (*1)
No. of bytes
Data part