3.25 MC (Master Control Relay), MCE (Master Control Relay End)

3.25 MC (Master Control Relay), MCE (Master Control Relay End)

Ladder diagram
Execution condition
X100
X101
Y131
X102
Y132
Outline of operation
● When the execution condition is ON, this instruction runs the program code between the MC
and MCE instructions.
● When the execution condition is OFF, the state of each I/O relay is as follows.
Type of instruction
OT
KP
SET
RST
TM
CT
SR
Differential instruction Refer to "Operation of differential instructions between MC and MCE".
Other instructions
(Note 1)
The following items are included in differential instructions.
3-76
Operation
All OFF.
Holds the state.
Reset.
Holds the current progress.
Not executed.
MC
Y131
Y132
MCE
WUME-FP7CPUPGR-12