Power Connection; Control System And External Device Connections - Extron electronics SMP 300 Series User Manual

Streaming media processor
Hide thumbs Also See for SMP 300 Series:
Table of Contents

Advertisement

Power Connection

100-240 VAC power input (see
A
IEC cord. Verify the front panel buttons and LCD illuminate (see
Operation

Control System and External Device Connections

The SMP 300 Series can be configured and controlled from the Remote RS-232 port (see
figure 4,
E
page 21) using SIS commands with DataViewer. A standard web browser can be used
for control and configuration from the LAN port. Because the LAN port must be connected
for streaming output, Extron recommends using it for configuration, remote control, and
firmware upgrades.
USB storage device — Attach an optional external USB storage device to the front or
B
rear USB ports to save recorded files. The storage device can be any standard external
hard drive or USB flash drive formatted with a compatible file system.
NOTE: The SMP 300 Series can detect and record to USB storage devices using
FAT32, VFAT long file name extensions, EXT2, EXT3, EXT4 file systems, or NTFS-
formatted storage volumes. For FAT32 USB storage, file sizes must be limited to
4 GB or the recording creates multiple 4 GB files.
USB keyboard and mouse, or RCP 101 — Connect a keyboard and mouse to the
C
two USB type A ports. With a keyboard and mouse connected, the user can toggle
<CtrL + ALT + S> the HDMI output (see figure 8) between the standard preview output
and the internal browser view.
Digital I/O — Connect to the four 3.5 mm, 5-pole captive screw ports to provide user-
D
defined digital inputs or outputs (see
Remote RS-232 — Connect the host RS-232 cable to the rear panel with
E
a 3-pole captive screw connector for bidirectional (±5 V) serial host control,
to control the SMP 300 Series using SIS commands over RS-232.
The default protocol port is:
9600 baud
1 stop bit
Reset button and LED — Press the button to reset the SMP 300 Series.
P
There are several reset modes to return the SMP to user-defined configuration
settings or to return all settings back to factory defaults.
The LED indicates the selected reset mode, and provides the reset status
during the reset operation (see
NOTE: The factory configured passwords for all accounts on this device have
been set to the device serial number. In the event of a complete system reset, the
passwords convert to the default, which is no password (see
on page 86 to change a password).
RJ-45 Ethernet connector (LAN) — Use a standard Ethernet cable to connect to a
Q
network. The default network settings are:
IP Address:
Subnet Mask:
Default Gateway: 0.0.0.0
DHCP:
NOTE: To connect the SMP 300 Series directly to a computer Ethernet port, use a
crossover Ethernet cable (see
figure 4
on page 26).
on page 15) or the front panel USB mini-B Config port (see figure 8,
no parity
no flow control (handshaking)
Rear Panel Reset
192.168.254.254
255.255.0.0
OFF
Connection Options
on page 15) — Connect the provided
Front Panel Menu
Digital I/O Configurator
on page 104).
8 data bits
on page 19).
on page 106).
SMP 300 Series • Installation
on
B
REMOTE
RS-232
Tx Rx
G
Users and Roles
16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smp 351Smp 351 3g-sdiSmp 352Smp 352 3g-sdi

Table of Contents