Cabling and Features

Attach cables using the following wiring diagrams as a guide. Full details are available in the IPCP Pro Q xi and xi Series User Guide.
CAUTION:
ATTENTION :
Total length of the power cord including the small pigtail shall not be less than 1.5 m or more than 4.5 m.
La longueur totale du câble d'alimentation, cordon compris, ne doit pas être inférieure à 1,5 m ou supérieure à 4,5 m.
Always use the power cord provided with the unit.
Veillez à toujours utiliser le câble d'alimentation fourni avec l'unité.
Should you need to use a different power cord, consult Extron Electronics prior to using the cord.
Si vous devez utiliser un autre câble d'alimentation, contactez Extron Electronics avant d'utiliser ce câble.
Power Input — Internal
INPUT
OUTPUT
100-240V ~ 10A MAX
100-240V ~ 10A MAX
50-60Hz
50-60Hz
Rear Panel
6 inch (152 mm)
IEC Input Cable
Power Output — Switched AC Power Output
INPUT
OUTPUT
100-240V ~ 10A MAX
100-240V ~ 10A MAX
50-60Hz
50-60Hz
Rear
Panel
ATTENTION:
When using the NEMA 5-15R receptacle
adapter, connect the equipment only to a
nominal 120 VAC electrical supply source.
Lorsque vous utilisez la prise de courant
NEMA 5-15R, veillez à ne connecter le
dispositif qu'à une source d'alimentation
nominale de 120 Vca.
Power Input, Internal Power Supply
• Connect to
• Front panel LED (
100 to 240 VAC.
during boot-up and remains lit
when the IPCP receives power.
Switched 100-240 VAC, 10 A (Max.) Power Output
6 inch (152 mm)
IEC Output Cable
• Front panel Power LED appears:
• Lit green (
) when power output is enabled (unit outputs power)
• Off (
) when power output is disabled (power output is off)
• Lit red (
) when a power output overcurrent condition is detected
(the circuit breaker has been tripped) and power output is disabled.
• Front panel Power button controls power output availability.
NOTE: The front panel power switch is not a safety disconnect
device. In case of emergency, disconnect AC power from the
power input (appliance inlet) of the connected equipment.
or
NEMA 5-15R
Adapter
) blinks
R
Front Panel
IEC Power Cord
IEC Power Cord
Edison Power Cord
NOTES:
Within the United States of America use a power supply cord
with conductors that are a minimum diameter of 18 AWG.
For international installations, use a power supply cord with
conductors that are a minimum of 1.0 mm
Make sure that the device being controlled can support an AC
power cycle.
POWER
CAUTION:
disconnect the
product from the
wall plug.
ATTENTION :
Veillez à toujours
déconnecter le
produit de la
prise murale.
To a 100 - 240 VAC
power source
(main power)
POWER
R
Front
Circuit Breaker
Panel
(power output
overcurrent
protection)
Power input port
on an AV device
(international)
Power input port
on an AV device
(USA)
.