Extron electronics SMP 300 Series User Manual page 142

Streaming media processor
Hide thumbs Also See for SMP 300 Series:
Table of Contents

Advertisement

Command Function
Record Resolution and Frame Rate
Set record resolution
View record resolution
Set record frame rate
View record frame rate
View record resolution
and frame rate (For
composite mode only)
View current recording
information (For
composite mode only)
X4#
KEY:
= Video bit rate
X4^
= Record resolution
X4&
= Record frame rate
X50)
= Stream selection
X50!
= Input number
X50@
= Output channel
X54#
= File size
Advanced Configuration
Overscan Mode
Set overscan mode
View overscan mode
X50$
KEY:
= Input video format
X51)
= Overscan
Test Pattern
Set test pattern
View test pattern
X56%
= Test patterns
KEY:
HDCP Settings (HDMI Inputs only)
View input HDCP status
Set input HDCP
authorization on
Set input HDCP
authorization off
View input HDCP
authorization
Enable HDCP
notification
Disable HDCP
notification
View HDCP notification
X(
= On/off
KEY:
X50!
= Input number
X51!
= HDCP status
X51@
= HDCP notification
SIS Command
(Host to Device)
E X50)
X4^
}
*
VRES
E X50)
}
VRES
E X50)
X4&
}
*
VFRM
E X50)
}
VFRM
33I
Example
1*I
Verbose mode 2/3
00200 to 10000 (5‑digit response)
480p, 720p, 1080p, 512x288, 1024x768, 1280x1024, Custom
1 = 30,
2 = 25,
3 = 24,
1 = Archive Channel A,
1 to 5
1 = A,
2 = B
File size in mega Bytes
E X50$
X51)
}
*
OSCN
E X50$
}
OSCN
1 = YUVp/HDTV (default),
0 = 0% (default: HDMI inputs), 1 = 2.5% (default: YUVp input), 2 = 5.0% (default: YUVi and composite inputs)
E X56%
}
TEST
E
}
TEST
0 = Off (default),
1 = Color bars, 2 = Aspect ratio 1.33, 3 = Aspect ratio 1.78,
5 = Crop, 6 = Pulse,
7 = Timestamp (composite mode only),
E
X50!
}
I
HDCP
E
X50!
}
E1*
HDCP
E
X50!
}
E0*
HDCP
E
X50!
}
E
HDCP
E
}
N1HDCP
E
}
N0HDCP
E
}
NHDCP
0 = Disabled/off (default),
1 to 5
0 = No sink/source detected, 1 = HDCP detected,
0 = Off (mute output to black), 1 = On (green HDCP notification‑screen, default)
Response
(Device to Host)
X50)
X4^ ]
Vres
*
X4^ ]
X50)
X4& ]
Vfrm
*
X4& ]
Horz resolution x Vert resolution*Frame rate
]
1280x 720*30
X50@
X50!
X4^
<ChA
*ChB
>*<
>*<
X50@
X50!
X4^
Inf*<ChA
*ChB
>*<
4 = 15,
5 = 12.5,
6 = 12,
2 = Archive Channel B (Dual Channel mode only),
X50$
X51)]
Oscn
*
X51)]
2 = YUVi,
3 = Composite
X56%]
Test
X56%]
X51!]
X50!
]
HdcpE
*1
X50!
]
HdcpE
*0
X(]
]
HdcpN1
]
HdcpN0
X51@]
1 = Enabled/on
2 = Sink/source detected but no HDCP
SMP 300 Series • Remote Communication and Control
Additional Description
]
X4&
X54#
X4#
]
>*<
>*<
>
X4&
X54#
X4#
]
>*<
>*<
>*<
>
7 = 10,
8 = 5
3 = Confidence
X50$
Sets input type
to overscan
X51)
mode
.
View the current overscan
X50$
for input type
.
4 = Aspect ratio 1.85,
8 = Universal OSD (composite mode only)
Turn HDCP authorized device
X50!
on for input
Turn HDCP authorized device
X50!
off for input
(default)
Enable green screen HDCP
notification (default)
Disable green screen HDCP
notification