The SMP sends the copyright messages under the following circumstances:

Password Information

NOTE: The factory configured passwords for all accounts on this device have been set
The ] Password: prompt requires a password (administrator level or user level) followed by
a carriage return. The prompt is repeated if the correct password is not entered.
If the correct password is entered, the unit responds with ] Login Administrator ] or
] Login User ] , depending on the password entered. If passwords are the same for both
administrator and user, the unit defaults to administrator privileges.

Error Responses

When the SMP is unable to execute the command, it returns an error response to the host.
The error response codes and their descriptions are as follows:
E10 – Unrecognized command
E12 – Invalid port number
E13 – Invalid parameter (number is out of range)
E14 – Not valid for this configuration
E17 – Invalid command for signal type

Using the Command and Response Tables

The
represent variables in the command and response fields. Command and response examples
are shown throughout the table. The SIS commands are not case sensitive. The ASCII to Hex
conversion table below is for use with the command and response table.
Space
Figure 94.
If the SMP is off and an RS‑232 connection is already set up (the PC is cabled to
the SMP and a serial communication program such as HyperTerminal is open), the
connected unit sends these messages via RS‑232 when first powered on.
If the SMP is on, it sends the copyright messages when a Telnet connection to the
SMP is first opened. The day of the week, date, and time are shown when the SMP is
connected via Telnet, but not via RS‑232. If using a Telnet connection, the copyright
message, date, and time is followed by a password prompt.
to the device serial number. In the event of a complete system reset, the passwords
convert to the default, which is no password (see
change a password).
Command and Response Tables
ASCII to Hex Conversion Table
ASCII to Hex Conversion
Users and Roles
E18 – System timed out
E22 – Busy
E24 – Privilege violation
E26 – Maximum connections exceeded
E28 – Bad file name or file not found
begins on page 114. Symbols used in the table
SMP 300 Series • Remote Communication and Control
on page 86 to
109