Command Function
IP Setup Commands (continued)
Set current port timeout
View current port
timeout
Set global IP port
timeout
View global IP port
timeout
X6(
KEY:
= Port timeout
RS-232 Port
Configure serial port
parameters
Reset serial port
View serial port settings
Set serial port receive
timeout
View serial port receive
timeout
X1(
KEY:
= Port timeout
X2)
= Intercharacter timeout Time in tens of milliseconds to wait between characters coming into a serial port before terminating
X2!
= Primary port status
X2@
= Length delimiter
X2%
= RS‑232 baud rate
X2^
= RS‑232 parity
X2&
= RS‑232 data bits
X2*
= RS‑232 stop bits
Front Panel Lock (Executive Mode)
Set Executive mode
View Executive mode
X5!
= Executive mode 0 = Off,
KEY:
RCP 101 Executive Mode
Executive mode on
Executive mode off
Query status
X(
KEY:
= On/off
SIS Command
(Host to Device)
E
X6(
}
0 *
TC
E
}
0 TC
E
X6(
}
1*
TC
E
}
1 TC
In tens of seconds, zero padded 1 to 65000 (default: 00030 = 300 seconds)
E
X2% , X2^ , X2& , X2*
}
1*
CP
E
}
1*9600,n,8,1CP
E
}
1CP
E
X1( * X2) * X2@ * X2!
}
1*
CE
E
}
1CE
Time in tens of milliseconds to wait for characters coming into a serial port before terminating
(min=0, max=32767, default: 10 = 100 ms). The response is returned with leading zeros.
(min=0, max=32767. Default: 2 = 20 ms). The response is returned with leading zeros. Commands using
X1(
X2)
both
and
must have both values = 0 or both set to non‑zero.
Parameter to set either the Length of message to receive, or the Delimiter value.
#
L=
=byte count (min=0, max=32767. Default=0L=0 byte count).
D = decimal value for ASCII character. (min=0, max=00255. Default=00000L).
Value is placed prior to parameter: 3 byte length = "3L" and ASCII 0A delimiter is "10D". The parameter is
case sensitive, must use capital D or capital L. The response is returned with leading zeros.
Priority status for receiving timeouts:
1
Configure
receive timeout command parameters (default = 0).
= Use
9600 (default), 19200, 38400, 57600, 115200 baud
O
E
N
dd,
ven,
one (default),
7, 8 (default)
1 (default), 2
X5!
X
X
1 = Complete lockout (no front panel control),
99 * 1X
99 * 0X
99 * X
0 = Disabled/off (default),
Response
(Device to Host)
X6( ]
Pti 0 *
X6( ]
X6( ]
Pti1 *
X6( ]
X2%
X2^
X2&
X2*]
Cpn 01
Ccp
,
,
,
X2%
X2^
X2&
X2*]
Cpn 01
Ccp
,
,
,
X2%
X2^
X2&
X2* ]
,
,
,
X1(
X2)
X2@
X2! ]
Cpn01
Cce
,
,
,
X1(
X2)
X2@
X2! ]
,
,
,
0 = Use Send data string command parameters when available,
M
S
ark,
pace
X5!]
Exe
X5!]
2 = Menu lockout,
]
Exe99*1
]
Exe99 *0
X( ]
1 = Enabled/on
SMP 300 Series • Remote Communication and Control
Additional Description
3 = Allow recording controls only