The Extron StudioStation 100 Streaming Media Processor is a compact, high definition recording and streaming device for
professional AV systems. It records MP4, M4A or M4V files of full screen HDMI video channel with mixed audio, and metadata.
It also supports live streaming at different resolutions and bitrates from the recording. The StudioStation 100 fits in presentation
recording, lecture capture, and enterprise training applications. It is ideal for installation beneath conference tables and in
lecterns. A RCP 101 remote control panel can be installed together with the StudioStation 100 to offer record controls and an
additional USB storage option.
This guide provides instructions for an experienced installer to set up and operate this streaming media processor. For full
installation, configuration, and operation details, see the StudioStation 100 User Guide, available at www.extron.com.
Mount the StudioStation 100
The StudioStation 100 is housed in a 1U high, half rack width metal enclosure that can sit on a table with the provided rubber feet
or mounted in a rack or under a table. Select a suitable mounting location, then choose an appropriate mounting option. Before
connecting the StudioStation 100, turn off all devices that will be connected and then make all external device connections to the
StudioStation 100 before applying power to the devices.
Rear Panel Overview
100-240V
0.7A
USB STORAGE
50-60 Hz
A
B
StudioStation 100 Rear Panel
Figure 1.
A
100-240 VAC IEC power inlet
B
USB type A port for external storage device and activity LED
C
HDMI input
Analog stereo audio input
D
HDMI preview output
E
Power Connection
100-240 VAC power inlet – Connect the provided IEC cord. Verify the front panel buttons and LCD illuminate (see
A
Panel Features
on page 3).
NOTE:
Make all external device connections to the StudioStation 100 before applying power to the devices.
Control System and External Device Connections
The StudioStation 100 can be configured and controlled from the rear panel RS-232 captive screw port (see figure 1,
front panel mini USB B Config port (see
and DataViewer. It can also be configured and controlled using a standard web browser from the LAN port (via telnet port 23).
Because the LAN port must be connected for streaming output, Extron recommends using it for configuration, control, and
firmware upgrades.
USB storage device and LED — Connect an optional external USB storage device to save recorded files. The activity LED
B
indicates the status of the USB port and blinks during recording. The storage device can be any standard external hard drive
or USB flash drive formatted with a compatible file system.
NOTE:
The StudioStation 100 can detect and record to USB storage devices using FAT32, VFAT long file name
extensions, EXT2, EXT3, EXT4 file system, or NTFS-formatted storage volumes.
INPUTS
OUTPUT
AUDIO
L
LINE
R
HDMI
HDMI
C
D
E
figure
3,
on page 3), or the LAN port ( see figure 1,
C
REMOTE
StudioStation 100
+12V
RS-232
CONTROL
1.0A MAX
RESET
Tx
Rx
G
F
G
H
I
F
RS-232 port for Simple Instruction Set (SIS™) control
G
USB type A port for remote control panel RCP 101
H
12V external power output to RCP 101
Reset button and LED
I
RJ-45 Ethernet LAN port
J
LAN
J
Front
), the
F
) using SIS commands
J
1

Advertisement

loading

Summary of Contents for Extron electronics StudioStation 100

  • Page 1 StudioStation 100, turn off all devices that will be connected and then make all external device connections to the StudioStation 100 before applying power to the devices. Rear Panel Overview 100-240V 0.7A INPUTS OUTPUT REMOTE StudioStation 100 AUDIO +12V RS-232 CONTROL USB STORAGE 1.0A MAX RESET...
  • Page 2: Input Connections

    (handshaking) Remote control port — Connect the StudioStation 100 with the RCP 101 EU/MK or decorator-style wallplate using a female type A USB connector. The RCP 101 has a USB Storage port, which provides an additional recording location.
  • Page 3: Front Panel Features

    • — Alarm LED Lights red when one or more alarms are triggered (see the StudioStation 100 User Guide for all alarms). — Config port Connect a control device to this port with a USB mini-B cable (not supplied). Use this port to send SIS commands to the StudioStation 100 for device configuration and control.
  • Page 4: Encoder Presets

    Powering Up When power is applied to the unit, the StudioStation 100 undergoes a self-testing sequence. The power LED starts blinking green when the power is connected but the unit is still booting. The green LEDs in the input and output section of the front panel light and the record controls buttons light amber.
  • Page 5: Recording Profiles

    Recording folders and files can be transferred directly from the StudioStation 100 to a computer on the same network using an SFTP client such as Filezilla, a free FTP program. Connect to the StudioStation 100 at sftp://<StudioStation 100 IP>:22022. Log in using admin or user credentials (see the StudioStation 100 User Guide at www.extron.com...
  • Page 6 NOTE: The StudioStation 100 can be accessed in Windows using Microsoft ® Internet Explorer ® version 10 or higher, Mozilla ® Firefox (version 35 or higher), or Google Chrome (version 37 or higher), and on a Mac platform (Mac OS X or ®...

This manual is also suitable for:

Smp 111