Method For Checking And Releasing Nitrogen Gas Charge Pressure In Accumula- Tor (For Control Circuit) - Komatsu D85EX-18 Operation & Maintenance Manual

Table of Contents

Advertisement

MAINTENANCE PROCEDURE
METHOD FOR CHECKING AND RELEASING NITROGEN GAS CHARGE PRES-
SURE IN ACCUMULATOR (FOR CONTROL CIRCUIT)
The accumulator is charged with high-pressure nitrogen gas, so improper operation may cause an ex-
plosion, which will lead to serious injury or death. For handling, always observe the following.
The pressure in the hydraulic circuit cannot be completely removed. When removing the hydraulic
equipment, do not stand in the direction that the oil spurts out when performing the operation. In
addition, loosen the bolts slowly when performing the work.
Do not disassemble it.
Do not bring open flame close to it or do not dispose of it in fire.
Do not perform drilling, welding or flame-cutting.
Do not hit or roll it, or subject it to any impact.
When disposing of it, the gas must be released. Ask your Komatsu distributor to have this work per-
formed.
NOTICE
If the nitrogen gas charge pressure in the accumulator is low and operations are continued, it becomes
impossible to release the remaining pressure inside the hydraulic circuit if a failure occurs on the ma-
chine.
FUNCTION OF ACCUMULATOR
The accumulator (1) stores the pressure in the control circuit.
Even after the engine is stopped, the control circuit can be op-
erated, so the following actions are possible.
If the control lever is operated in the direction to lower the
work equipment, it is possible for the work equipment to go
down under its own weight.
The pressure in the hydraulic circuit can be released.
METHOD FOR CHECKING FUNCTION OF ACCUMULATOR
When operating the blade control lever to lower the blade, check the safety around the machine.
NOTICE
If the nitrogen gas charge pressure in the accumulator is low and operations are continued, it becomes
impossible to release the remaining pressure inside the hydraulic circuit if a failure occurs on the ma-
chine.
Replace the accumulator every 2 years or every 4000 hours, whichever comes sooner.
Check the nitrogen gas charge pressure as follows.
1.
Stop the machine on a firm and flat ground.
4-64
k
k
WARNING
k
k
CAUTION
MAINTENANCE

Advertisement

Table of Contents
loading

This manual is also suitable for:

D85px-1822001

Table of Contents