Komatsu D85EX-18 Operation & Maintenance Manual page 122

Table of Contents

Advertisement

EXPLANATION OF COMPONENTS
4.
When countdown reaches 0, the engine stops and the
screen changes to the "Auto Idle Stop in Operation"
screen.
5.
To prevent battery discharging, turn off unnecessary
switches.
REMARK
While the auto idle stop is activated, only the engine is
stopped and the machine monitor, inverter, etc., as well as
the electrical components including the air conditioner, ra-
dio, lamps, and wipers keep their states before the engine
is stopped.
To prevent battery discharging, turn the starting switch to
OFF position.
6.
When restarting the engine, turn the starting switch as usual.
AFTERTREATMENT DEVICES REGENERATION
Each item of "Aftertreatment Devices Regeneration" menu (c)
is to make settings for aftertreatment devices regeneration.
For details of aftertreatment devices regeneration, see "HAN-
DLE Komatsu Diesel Particulate Filter (KDPF) (3-103)".
The operation methods and the contents of the display of
KDPF regeneration and urea SCR regeneration are common.
SCR INFORMATION
Each item in "SCR Information" menu (d) is for displaying the
information related to SCR and DEF.
For details of SCR Information, see "HANDLE UREA SCR
SYSTEM (3-113)".
MAINTENANCE SCREEN SETTING
Each item of setting menu (e) on "Maintenance" screen is used
for displaying and setting the notification relevant to mainte-
nance.
The items on the "maintenance" display are as follows.
A
Air Cleaner Cleaning or Change
Coolant Change
Fuel Prefilter Change
Engine Oil Change
Engine Oil Filter Change
P/T Oil Filter Change
3-68
B
-
-
500
500
500
500
OPERATION

Advertisement

Table of Contents
loading

This manual is also suitable for:

D85px-1822001