Method For Lubricating - Komatsu D85EX-18 Operation & Maintenance Manual

Table of Contents

Advertisement

MAINTENANCE
3.
Tilt switch for the fuel feed pump (2) which is located in the
upper rear left of the engine to ON position.
Lamp (3) flashes and the fuel feed pump operates.
After the specified time (approximately 7 minutes), lamp
(3) goes out automatically and the fuel feed pump stops.
When lamp (3) goes out, air bleeding is completed.
4.
If the fuel circuit is empty after the machine stops because
of running out of fuel, or the fuel hose and tubes are serv-
iced, or the supply pump is replaced, perform the following
procedure.
1)
After the fuel feed pump stops automatically (the lamp goes out), turn fuel feed pump switch (2) to ON
position again.
2)
Check that lamp (3) has gone out.
5.
Start the engine.
6.
After the engine starts, run it for approximately 5 minutes to bleed all air from the fuel circuit.
If the engine does not start, all air may not be bled. Repeat the operations of steps 1 to 6 again.
NOTICE
Keep away from the engine while it is being started and running.
Do not turn the starting motor continuously for more than 20 seconds.
If the engine does not start, wait for 2 minutes or so, and then try to start the engine again.
REMARK
The fuel feed pump switch has a timer in it. It starts and stops the pump automatically.
The fuel feed pump stops while the lamp is flashing, but this is not abnormal.
If the switch is turned to OFF position while the lamp is lit, the lamp goes out and the fuel feed pump
stops.

METHOD FOR LUBRICATING

1.
Lower the work equipment to the ground.
2.
Stop the engine.
3.
Remove the cover under the monitor and control panel.
4.
By using a grease pump, pump in grease through the
grease fittings.
(1) Brake pedal
(2) Decelerator pedal
(3) Brake rod
5.
After greasing, wipe off any old grease that is pushed out.
MAINTENANCE PROCEDURE
4-39

Advertisement

Table of Contents
loading

This manual is also suitable for:

D85px-1822001

Table of Contents