Method For Replacing Door Damper; Method For Lubricating Door Hinge - Komatsu D85EX-18 Operation & Maintenance Manual

Table of Contents

Advertisement

MAINTENANCE
1.
Loosen seal bolt (1) slowly.
If oil oozes out through the thread portion, the oil level is
not low. Tighten the bolt as before.
If no oil oozes out, perform the following step 2.
REMARK
Seal bolt (1) of the idler is not seen until the outside side
cover is removed.
2.
Remove seal bolt (1).
If no oil oozes, the oil level is low. Ask your Komatsu dis-
tributor for repair.

METHOD FOR REPLACING DOOR DAMPER

Measure groove depth (A) of door damper rubber (1).
When groove depth (A) decreases to 2 mm or less, replace the
damper.
The damper is installed at top and bottom, 2 pieces each on
the R.H. and L.H. doors.

METHOD FOR LUBRICATING DOOR HINGE

Perform this when the door creaks when it opens or closes.
MAINTENANCE PROCEDURE
4-33