Figure 37: Dc Terminal Block; Figure 38: Stripped Wire - Allied Telesis 8100L Series Installation Manual

Fast ethernet switches
Table of Contents

Advertisement

Chapter 5: Powering On the Switch
92
Positive
Terminal
3. With a 14-gauge wire-stripping tool, strip the three wires in the tray
cable coming from the DC input power source to 8mm  1mm (0.31 in.,
 0.039 in.), as shown in Figure 38 on page 92.
Warning
Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by
leaving exposed wire on the terminal block after installation.  E10
4. Insert the power supply ground wire into the middle connector of the
DC terminal and tighten the connection with a flathead screwdriver, as
shown in Figure 39 on page 93.
Warning
When installing this equipment, always ensure that the power supply
ground connection is installed first and disconnected last.  E11
Ground
Terminal
Figure 37. DC Terminal Block
Stripped Wire
Figure 38.
Negative
Terminal