DAF 95XF Series Manual page 39

Hide thumbs Also See for 95XF Series:
Table of Contents

Advertisement

1
95XF series
COMPLAINT: PUMP FAILS TO GENERATE PRESSURE
Possible cause
Reservoir level too low.
Leaking inlet valve (ball).
Worn or damaged "O"-rings on the two-way
valve.
Pressure release valve incorrectly set.
COMPLAINT: CAB LOCK CANNOT BE OPENED
Possible cause
Damaged or broken pipe.
Jammed piston in locking mechanism.
Possible cause
Jammed piston in cab locking mechanism.
Pump fails to generate pressure.
0209
Top up the reservoir.
Remove the two-way valve and check the
inlet valve. Clean it or fit a reconditioning set.
Fit a reconditioning kit.
Check the pressure release valve (using a
pressure gauge only) and adjust, if
necessary.
Replace pipe or connection.
Repair or replace the locking mechanism.
COMPLAINT: CAB CANNOT BE TILTED
Repair or replace the locking mechanism.
Check the operation of the pump.
DIAGNOSTICS
Cab suspension
Remedy
Remedy
Remedy
1
2-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents