DAF 95XF Series Manual page 217

Hide thumbs Also See for 95XF Series:
Table of Contents

Advertisement

1
95XF series
Tilting the cab back
1
7
Turn the two-way valve (2) on the pump (1) to
the left (position B). The pressure which has
built up in the pump will be passed on to the
pressure side of the lifting cylinder (3) and will
simultaneously activate the non-return valve (5)
in the cylinder.
Each stroke of the pump opens the non-return
valve (5). When the non-return valve in the
lifting cylinder opens, oil can flow back into the
pump reservoir from the return side of the lifting
cylinder (3). The cab can therefore only be tilted
back when pressure has built up in the pump.
The pressure in the pump and the pipes drops
at the end of each pump stroke. The non-return
valve now closes. The cab will fall downwards
on its own a few centimetres before it is
completely secured in the locks. This is due to
the fact that the cylinder piston is in the position
which allows a "leak-off" connection (4) between
the areas above and below the cylinder piston.
The warning lamp on the CWS panel will switch
off then.
0209
B
2
8
6
CAB TILTING MECHANISM
3
4
5
6
General
K1 00 707
6
2-3

Hide quick links:

Advertisement

Table of Contents
loading