Dp Clean High Flow Purge/Solvent Flush Option; External Evacuation System - Edwards GXS Series Instruction Manual

Dry screw vacuum pump
Table of Contents

Advertisement

Table 16 Water consumption data (GXS750/2600/4200)
Ambient (°C)
40
30
20

2.7 DP clean high flow purge/solvent flush option

Table 17 High flow purge/solvent flush data
Feature
Pneumatic valve gas
supply
Pneumatic valve inlet
connection
High flow purge gas
High flow purge air filter
DP clean solvent flush
fluid inlet connection
DP clean solvent suction
pipe connection
Notes:
1. The high flow purge/solvent flush kit is available as an option.
2. The DP clean solvent suction pipe is supplied with the pump but not fitted.

2.8 External evacuation system

The pumpdown performance on dry pumping systems fitted with mechanical boosters
can be further enhanced by the use of an External Evacuation System (EES) kit. The EES
kit will only provide performance improvement on pumpdown cycles lasting less than
30 seconds to pressures below 0.1 mbar. The EES kit must only be used on clean
applications.
M58800880_H - Technical data
Water Temperature (°C)
40
25 SLM
2 bar dP
20 SLM
1.3 bar dP
15 SLM
0.75 bar dP
Specification
Nitrogen or clean dry air
3/8 inch compression fitting
Air, nitrogen or other inert
gas which is compatible with
process
1/2 inch NPT male
(available as a spare, refer to
Spares
on page 79)
3/8 inch BSP male
3/8 inch BSP female
Page 27
30
20 SLM
1.3 bar dP
20 SLM
1.3 bar dP
15 SLM
0.75 bar dP
2.5 - 6.9 barg
(36 - 100 psig)
Typically 170 slm (for the
GXS160 and GXS250 systems)
and 185 slm (for the GXS450
and GXS750 systems) at
atmospheric pressure at the
purge inlet connection
20
15 SLM
0.75 bar dP
15 SLM
0.75 bar dP
15 SLM
0.75 bar dP
Rating

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents