Warnings; Led Warning Indicators - Edwards GXS Series Instruction Manual

Dry screw vacuum pump
Table of Contents

Advertisement

Cause
The pump must be stopped before starting the solvent soak.
Remedy
Stop the pump and then repeat the command.
Fault
Event 331.42
Cannot start Command. The pump is not warmed up.
Cause
The pump must be warmed up and in the green mode/standby mode to initiate
the DP Clean sequence.
Remedy
- Either reduce the warm up temperature (refer to
temperature
Disabling the warm-up cycle
- Make sure that the pump is in green mode/standby mode before attempting the
DP Clean.
Fault
Event 331.43
Cannot start Command. the pump is not in the green mode.
Cause
The pump must be in the green mode/standby mode to initiate the DP Clean
sequence.
Remedy
Set the pump into green mode/standby mode and then start the DP clean.
Fault
Event 331.46
Cannot start command. The pump is not running.
Cause
The pump must be running to initiate the DP Clean sequence.
Remedy
-

10.2 Warnings

The pump controller generates a warning when a problem is encountered.
By default, the pump is prevented from going on‑process when there are active
warnings so it is important to investigate the cause of the warning. It is possible to
configure the pump so that it will go on‑process with the active warnings. Refer to
a pump to go on-process with a warning
Once the problem that caused a warning has been resolved, the warning is cleared by
the pump controller.

10.2.1 LED warning indicators

If the pump encounters a problem, warnings are indicated on the LEDs on the front
control panel, the rear panel and on the PDT if fitted.
The warning LEDs on the front control panel and rear panel illuminate continuously
when a warning is generated.
M58800880_H - Fault finding
on page 136), enable the pump on‑process when cold (refer to
on page 136) or wait for the pump to warm up.
Page 162
Lowering the warm-up
on page 137 for more information.