Warn On-Process Menu; On-Process Ramp Menu - Edwards GXS Series Instruction Manual

Dry screw vacuum pump
Table of Contents

Advertisement

Table 38 DP clean options menu
Option
Set clean speed
Clean time
Automatically start on
entering Green Mode
Inlet purge open during
clean cycle
Inlet purge time after
clean cycle
Allow DP clean when
pump is on process
Automatically run DP
clean during shutdown
Allow DP clean when
pump is on process
Automatically run DP
clean during shutdown
* Scroll through the options by pressing the UP/DOWN keys. Press ENTER to accept the
new setting. Press CANCEL to exit back into the DP clean menu.
Press the UP/DOWN keys to select enable/disable and press ENTER to accept or CANCEL
to exit back to the DP clean menu.

9.4.11 Warn on-process menu

Press the UP/DOWN keys to select enable/disable and press ENTER to accept or CANCEL
to exit back to the Set sequences menu.

9.4.12 On-process ramp menu

Scroll by pressing the UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to
exit back to the Set sequences menu.
Table 39 On-process ramp options menu
Option
Time between speed step
changes
Size of speed step changes
Scroll through the options by pressing the UP/DOWN keys. Press ENTER to accept the
new setting. Press CANCEL to exit back into the On‑process ramp menu.
M58800880_H - Pump display terminal
Text on PDT line 2
Set DP Speed...
Clean Time...
Start in Green Mode ...
Inlet Purge...
Purge Time
Allow on Process
Auto On Shutdown
Allow on Process
Auto On Shutdown
Text on PDT line
2
Ramp Time...
Ramp Step...
Page 127
Options on PDT line 2 after
pressing Enter
Range 20 to 110 Hz*
Range 10 minutes to 60 minutes*
Enable/Disable
Enable/Disable
Range 0 minutes to 60 minutes*
Enable/Disable
Enable/Disable
Enable/Disable
Enable/Disable
Options on PDT line 2 after pressing
Enter
Range 0 ‑ 3600 seconds in 60 second
steps
Range 5 to 110 Hz in Hz steps

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents