Event/Warning/Alarm Display And Acknowledgement; Menus - Edwards GXS Series Instruction Manual

Dry screw vacuum pump
Table of Contents

Advertisement

Table 28 PDT displays
Pump state
Press Start button PDT displays:
Stopped
Running
Stopped or Running
Press Stop button PDT displays:
Stopped
Running
Stopped or Running

9.3 Event/warning/alarm display and acknowledgement

Each new event/warning/alarm is displayed when it occurs, overwriting any text already
present unless another unacknowledged event/warning/alarm is currently being
displayed. The corresponding warning/alarm LED flashes to indicate a new event/
warning/alarm.
Pressing ENTER acknowledges the event/warning/alarm currently displayed and the
warning/alarm LED stops flashing. If available, the display will show the suggested
action, press ENTER again to clear.
If there is another new event/warning or alarm the warning/alarm LED will continue to
flash and this is then displayed, otherwise the display will revert to the original text from
before the alarms/warnings/events occurred.
If there are warnings/alarms still present, but they are all acknowledged, then the
corresponding LED remains continuously illuminated. The text indicating acknowledged
warning/alarm conditions still present may be viewed in the Status menu, refer to status
menu contents in
remain present until the pump is manually started from the PDT or front panel controls.
Once all warning/alarm conditions have gone away, then the corresponding LED is
extinguished.
To avoid a build‑up of out of date warnings, they are automatically acknowledged after
36 hours.

9.4 Menus

There are three menu buttons NORMAL, STATUS and SETUP described below.
M58800880_H - Pump display terminal
Local control
PDT display
LED
On
START MENU
Start Pump
On
Pump Running
Press CANCEL
Off
No PDT Control
Press CANCEL
On
PUMP Stopped
Press CANCEL
On
STOP MENU
Auto Shutdown
Off
No PDT Control
Press CANCEL
Status menu
on page 122. Some alarms such as 1.01 STOP ACTIVATED
Page 121
Operator
Press ENTER to confirm
Press CANCEL
Press CANCEL
Press CANCEL
If Fast Shutdown is
required, press the
down arrow. Press
ENTER to confirm
Press CANCEL
Pump response
Pump starts
No change
(running)
No change
No change
(stopped)
Pump stops
No change

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents