How To Set Up The Mcm Microtim Using The Pdt; Figure 74 Ascii Settings Screenshot - Edwards GXS Series Instruction Manual

Dry screw vacuum pump
Table of Contents

Advertisement

Figure 74 ASCII settings screenshot

In the HyperTerminal window, type: '?T' and press the ENTER key.
If successful, you should get a reply with the following format:
157,28,19,42,0,72,121,35,0
In this example:
157
28
19
42
0
72
121
35
0
Refer to the SIM manual for more information about the various field elements and
what they mean for the system. Any other query and command can be sent by typing
the operation and parameter followed by the ENTER key.

9.14 How to set up the MCM MicroTIM using the PDT

If the MCM MicroTIM is fitted to the system, all the pump configuration settings that are
made using the PDT are automatically stored in the MicroTIM. This means that if a new
system is fitted, for example, while servicing the existing system, there is no need to
configure the new pump settings if the original MicroTIM is used.
The PDT can also be used to configure the channel 2 input and channel 4 output on the
MCM MicroTIM itself. Refer to the MicroTIM instruction manual D37360880 for full
information about MicroTIM installation and setup.
The following menus are used by the PDT to configure the MCM MicroTIM channel 2
input and channel 4 output.
M58800880_H - Pump display terminal
indicates the pump controller
indicates the GXS pump family
indicates the GXS250
indicates the GXB2600 booster
indicates the GXS screw pump
indicates low volts, 7.5 kW DP and 7.5 kW BP
indicates a harsh gas module
indicates a normal thermal management type
indicates a normal exhaust type