Table 42 Smart stop options menu
Option
Smart stop enable/disable Enable/Disable...
Time for pump to stop
Size of speed step changes Step size...
Temperature to stop pump
once reached
Time after temperature is
reached before pump
stops
* Scroll through the options by pressing the UP/DOWN keys. Press ENTER to accept the
new setting. Press CANCEL to exit back into the Smart stop menu.
Press the UP/DOWN keys to select enable/disable and press ENTER to accept or CANCEL
to exit back to the Smart stop menu.

9.4.16 Speed control options menu

Scroll by pressing the UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to
exit back to the Set sequences menu.
Table 43 Speed control options menu
Option
Set speed control dry
pump
Set speed control
booster
Set the second speed
* Scroll through the options by pressing the UP/DOWN keys. Press ENTER to accept the
new setting. Press CANCEL to exit back into the Speed control menu.

9.4.17 Reset MicroTIM

Empties the MicroTIM configuration set storage of any configurations that have been
loaded there.
M58800880_H - Pump display terminal
Text on PDT line 2
Stop time...
Setpoint...
Settle time...
Text on PDT line 2 Options on PDT line 2 after pressing Enter
Dry pump...
Booster...
Second Speed...
Page 129
Options on PDT line 2 after pressing
Enter
Enable/Disable
Range 0 ‑ 3600 seconds in 60 second
steps*
Range 20 to 110 Hz*
Range 0-210 °C*
Range 1-200 seconds*
Select from:
Normal/PID
External Voltage
SIM protocol
Second speed
Select from:
Normal
External Voltage
SIM protocol
Second speed
Range 20 - 110 Hz*