9.6.7 Allow a pump to go on-process with a warning
By default a pump is prevented from going on‑process if a warning is present. This can
be disabled using the Warn onprocess menu item which can be found by going to the
Setup menu and selecting the Set sequences menu.
9.6.8 Warm soft start
This enables a feature where, once warmed‑up to go on‑process, the pump is returned
to the off‑process speed for a configurable time ("WrmSftStartTime") before it goes on
process.
9.7 How to configure the booster pump behaviour
By default the booster pump starts a set time after the dry pump starts. The booster
stops at the same time as the dry pump.
It is possible to change the behaviour of the booster pump so that it can be controlled
manually or so that the time delay can be changed or that it starts after the inlet
isolation valve is open.
Note:
A pump with a tool interface can control the booster independently. Refer to
the channel 2 input
The following menus are used by the PDT to configure the booster:
Figure 59 Booster PDT menu configuration items
9.7.1 Setting the booster to manual operation
The booster can be set to manual mode using the BP Start mode menu item.
M58800880_H - Pump display terminal
‑ duty gas module do not have inlet purge so it is not possible to
on page 157 for details on configuring this behaviour.