Ip Configuration Menu - Edwards GXS Series Instruction Manual

Dry screw vacuum pump
Table of Contents

Advertisement

Table 46 Table: Accessory menu
Accessory
Isol Valve...
Water Sensor...
Active gauge...
N2 Flow Sensor...
Exh Pressure...
DP Clean...
Auxiliary gauge...
PT100 1...
PT100 2...
Pressure...
Pressure 2...
Max pressure 1...
Max Pressure 2...
Gas Ballast...
For an accessory, press the UP/DOWN keys to select Fitted or Not Fitted and press
ENTER to accept or CANCEL to exit back to the Commands menu.
Note:
The inlet isolation valves additionally have an option of fitted no feedback for use where
there are no position feedback switches fitted to the inlet isolation valve.

9.4.23 IP configuration menu

Under the Setup menu. Scroll by pressing the UP/DOWN keys. Press ENTER to open a
sub menu or CANCEL to exit back to the Setup menu.
Table 47 Configuration menu
Configuration
Host_Name...
DHCP Enable...
IP Address...
Address Mask...
Gateway...
DNS Server...
NTP Server...
SMTP Server...
MAC Address...
M58800880_H - Pump display terminal
Parameter
(Inlet isolation valve)
(Purge gas flow)
(Exhaust Pressure Sensor)
Choice of Voltage/Strain Gauge/Pirani Gauge
xxxxmbar
xxxxmbar
(Additional gas ballast for the GXS450 and GXS750 systems
fitted with the medium duty gas module only)
Page 131
Display
(display only)
(Enabled / Disabled)*
(xxx.xxx.xxx.xxx)†
(xxx.xxx.xxx.xxx)†
(xxx.xxx.xxx.xxx)†
(xxx.xxx.xxx.xxx)†
(display only)
(display only)
(display only)