Mode; Cvcc - Chroma 63200A Series Operation & Programming Manual

High power dc electronic loads
Table of Contents

Advertisement

3.7.5
CZ Mode
In CZ mode, the Load will sink a current according to the programmed impedance.
Impedance can be programmed by set the equivalent series resistance Rs, equivalent series
inductance Ls, equivalent parallel load capacitance C
and Ip (max) parameters for loading when operating in this mode.
To enter into CZ mode, press
Parameters:
C
: Set the level of equivalent parallel load capacitance C
L
R
: Set the level of equivalent parallel load resistance R
L
mode high range.
Ls: Set the level of equivalent series inductance Ls. The range is 0.1μH to 20μH.
Rs: Set the level of equivalent series resistance Rs. The range is 30mΩ to 20Ω.
It is suggested to use a remote sense cable to measure the UUT output
CAUTION
voltage.
3.7.6

CVCC

In CVCC mode, the Load will adjust the sink current to control the output voltage of current
source by the programmed voltage. Constant voltage has three types of response speed:
fast, normal and slow.
To enter into CVCC mode, press
I
Parameters:
V_SET: Set the voltage level.
ADVA
and select CZ and then press Enter.
Figure 3-2 Constant Impedance Mode
ADVA
and select CVCC and then press Enter.
CC
CV
CV+CC mode:I/V Curve
Operation Overview
, equivalent parallel load resistance R
L
. The range is 30μF to 50,000μF.
L
. The range is the same as the CR
L
V
L
3-27