Chroma 63200A Series Operation & Programming Manual page 93

High power dc electronic loads
Table of Contents

Advertisement

High Power Electronic Load 63200A Series Operation & Programming Manual
Query Syntax:
Return Parameters:<NR1>, [Unit = None]
Query Example:
[ADVance:]OCP:DWELl
Type:
Description:
Setting Syntax:
Setting Parameters:<NRf+>, 10μs ~ 1s Resolution = 10μs, Unit = Second
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = Second]
Query Example:
[ADVance:]OCP:TRIGger:VOLTage
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = Volt]
Query Example:
[ADVance:]OCP:SPECification:H
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = Ampere]
Query Example:
4-30
OCP:STEP MIN
[ADVance:]OCP:STEP?[<space><MAX | MIN>]
OCP:STEP?
OCP:STEP? MAX
OCP:STEP? MIN
Channel-Specific
Set dwell time for OCP test mode.
[ADVance:]OCP:DWELl<space><NRf+>[suffix]
OCP:DWEL 0.5
OCP:DWEL 500ms
OCP:DWEL MAX
OCP:DWEL MIN
[ADVance:]OCP:DWELl?[<space><MAX | MIN>]
OCP:DWEL?
OCP:DWEL? MAX
OCP:DWEL? MIN
Channel-Specific
Set trigger voltage for OCP test mode.
[ADVance:]OCP:TRIGger:VOLTage<space><NRf+>[suffix]
OCP:TRIG:VOLT 0.5
OCP:TRIG:VOLT 500mV
OCP:TRIG:VOLT MAX
OCP:TRIG:VOLT MIN
[ADVance:]OCP:TRIGger:VOLTage?[<space><MAX | MIN>]
OCP:TRIG:VOLT?
OCP:TRIG:VOLT? MAX
OCP:TRIG:VOLT? MIN
Channel-Specific
Set high level current of specification for OCP test mode.
[ADVance:]OCP:SPECification:H<space><NRf+>[suffix]
OCP:SPEC:H 0.5
OCP:SPEC:H 500mA
OCP:SPEC:H MAX
OCP:SPEC:H MIN
[ADVance:]OCP:SPECification:H?[<space><MAX | MIN>]
OCP:SPEC:H?
OCP:SPEC:H? MAX
OCP:SPEC:H? MIN
Set step count = minimum value.
Set off time = 0.5s.
Set off time = 0.5s.
Set off time = maximum value.
Set off time = minimum value.
Set trigger voltage = 0.5V.
Set trigger voltage = 0.5V.
Set trigger voltage = maximum value.
Set trigger voltage = minimum value.
Set high level current = 0.5A.
Set high level current = 0.5A.
Set high level current = maximum
value.
Set high level current = minimum
value.