Table 3-4 Pin Assignments of 63200A Series I/O Port Connector
Pin
1
EXT_WAVE_I
2
EXT_WAVE_V
3
4
SHORT_ST
5
TRIG_DIGI
1. Pin [1:2]: EXT_WAVE[I:V] the external waveform input signal with
2. Pin [3:14:15]: the GND signal.
3. Pin [4]: SHORT ST the Short ON output signal, TTL Level and
4. Pin [5]: the trigger source for TRIG_DIGI external trigger input signal
5. Pin [6]: the Load ON output signal, TTL Level and Active High.
6. Pin [7]: TRIG_ SEQ  the external input signal is automatically
7. Pin [8:9]: DO[1:2] the binary digital output signal, high level: 4.7kΩ
8. Pin [10]: DO3
9. Pin [11:12]: DI[1:2] provides External Load ON/OFF function so that
3.3.4

Extended Communication Interface

The GPIB communication interface can be expanded. The user should know the GPIB
address when using PC with GPIB to remote programming the Electronic Load. Every
device that connects to the GPIB interface will be assigned a unique address.
Figure 3-3 63200A Series I/O Port Connector
Signal
Pin
6
7
GND
8
9
10
input range from 0 to 10V.
Active High.
to be become digital. TTL Level, falling edge and pulse width ≥1μs.
triggered in the following sequence: TTL Level, falling edge, and
pulse width ≥1μs.
resistance increases to 5V, low level <0.6V, loading current = 10mA.
the user can use the input signal to control Load ON/OFF externally.
When DI1 and DI2 are both set to External Load ON/OFF, both
signals need to be HIGH to Load OFF and on the contrary both
signals need to be LOW to Load ON.
When DI1 (or DI2) is set to Remote Inhibit and Low, all channels in
the Electronic Load are Load OFF and a message of REMOTE
INHIBIT will appear. If this protection is not cleared, even the DI1 (or
DI2) is High, Load on cannot be executed. DI1 and DI2 are for
communication control and the action time should be less than 5ms.
Signal
Pin
LOAD_ON_ST
TRIG_SEQ
DO1
DO2
DO3
Operation Overview
Signal
11
DI1
12
DI2
13
DI3
14
GND
15
GND
3-7