Constant Resistance Mode - Chroma 63200A Series Operation & Programming Manual

High power dc electronic loads
Table of Contents

Advertisement

manually switch between the two programmed states. Slew rate determines the rate at
which Load level changes from one load level state to another. Figure 3-5 shows the current
level of load after pressing
State A=4A, State B=2A, Rise
Current
rise slew rate
4A
2A
3.6.2

Constant Resistance Mode

In CR mode, the Load will sink a resistance in accordance with the programmed value
regardless of the input voltage. To enter into the CR mode, press the
CR mode.
L 1 =
1 0 0 0 . 0 0
L 2 =
1 0 0 0 . 0 0
0 . 0 0 0 V
C R _ H
L 1 =
1 0 0 0 . 0 0
L 2 =
1 0 0 0 . 0 0
0 . 0 0 0 V
C R _ H
A/ B
key.
=0.2A/μs, Fall
10uS
25uS
Figure 3-5 Load Level after Pressing
Ω
S R  =
Ω
S R  =
V o n
Ω
I _ R A N G E =
Ω
V o n
=0.08A/μs
fall slew rate
State A
State B
Time
press key "A/B"
A/ B
0 . 0 0 5
0 . 0 0 5
0 . 0 0 0 A
0 . 0 0 0 0
=
0 . 0 0 0
H I H G ( 2 )
0 . 0 0 0 A
0 . 0 0 0 0
=
0 . 0 0 0
Operation Overview
Key
MODE
key and select
A / u s
C C
A / u s
C R
C V
W
C P
V
C C
C R
C V
W
C P
V
3-17