3.7.11
UDW (User Defined Waveform)
The User Defined Waveform is able to simulate the actual sinking current and capture or edit
the current through oscilloscope. The graphical operating software can easily save the
waveform in the internal memory of 63200A Series Electronic Loads and the user defined
waveform can be sunk as desired.
W A V E
=
I N T E R V . =
0 . 0 0 0 V
0 . 0 0 0
V p +
U D W _ H
C H A I N
=
0 . 0 0 0 V
0 . 0 0 0
V p +
U D W _ H
Parameters:
WAVE: Select the internal 10 stored memories.
INTERV: Set the interval for update.
REPEAT: Set the number of time to repeat.
INTERP: Set the open linear interpolation.
CHAIN: Set to link other memory.
3.7.12
EXTERNAL WAVE Control
In External Wave Control mode, it will sink following the selected mode and external
waveform. The EXT V/I input connector is located on the Digital IO of rear panel. The
external signal 0 to 10V maps to the sinking condition from 0 to full scale. The external
signal is also applicable for 0 to 10V DC voltage bias.
1
0 . 0 1
m s
0 . 0 0 0
V o n
0
0 . 0 0 0
V o n
R E P E A T
=
0
I N T E R P . =
N O ( 0 )
0 . 0 0 0 A
V p -
0 . 0 0 0 0
=
0 . 0 0 0
0 . 0 0 0 A
V p -
0 . 0 0 0 0
=
0 . 0 0 0
Operation Overview
C C
▼
C R
C P
W
C V
V
▲
C C
C R
C P
W
C V
V
3-31