High Power Electronic Load 63200A Series Operation & Programming Manual
Return Parameters:<NR2>, [Unit = Second]
Query Example:
CURRent:DYNamic:REPeat
Type:
Description:
Setting Syntax:
Setting Parameters:<NRf+>, 0 ~ 65535, Resolution = 1, Unit = None
Setting Example:
Query Syntax:
Return Parameters:<NR1>, [Unit = None]
Query Example:
CURRent:DYNamic:RISE
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = A/μs]
Query Example:
CURRent:DYNamic:FALL
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = A/μs]
Query Example:
4-18
CURR:DYN:T2?
CURR:DYN:T2? MAX
CURR:DYN:T2? MIN
Channel-Specific
Set the repeat count for constant current dynamic mode.
CURRent:DYNamic:REPeat<space><NRf+>
CURR:DYN:REP 500
CURR:DYN:REP MAX
CURR:DYN:REP MIN
CURRent:DYNamic:REPeat?[<space><MAX | MIN>]
CURR:DYN:REP?
CURR:DYN:REP? MAX
CURR:DYN:REP? MIN
Channel-Specific
Set the rising slew rate of current for constant current dynamic
mode.
CURRent:DYNamic:RISE<space><NRf+>[suffix]
CURR:DYN:RISE 2.5
CURR:DYN:RISE 1A/μs
CURR:DYN:RISE MAX
CURR:DYN:RISE MIN
CURRent:DYNamic:RISE?[<space><MAX | MIN>]
CURR:DYN:RISE?
CURR:DYN:RISE? MAX
CURR:DYN:RISE? MIN
Channel-Specific
Set the falling slew rate of current for constant current dynamic
mode.
CURRent:DYNamic:FALL<space><NRf+>[suffix]
CURR:DYN:FALL 2.5
CURR:DYN:FALL 1A/μs
CURR:DYN:FALL MAX
CURR:DYN:FALL MIN
CURRent:DYNamic:FALL?[<space><MAX | MIN>]
CURR:DYN:FALL?
CURR:DYN:FALL? MAX
Set repeat count = 500
Set repeat count = maximum value.
Set repeat count = minimum value.
Set rising slew rate to 2.5A/μs.
Set rising slew rate to 1A/μs.
Set rising slew rate to the maximum
value of dynamic load.
Set rising slew rate to the minimum
value of dynamic load.
Set falling slew rate to 2.5A/μs.
Set falling slew rate to 1A/μs.
Set falling slew rate to the maximum
value of dynamic load.
Set falling slew rate to the minimum
value of dynamic load.